Boiler De Gas De 8700 Kcal H - Sheffield Food

Boiler De Gas De 8700 Kcal H - Sheffield Food

  • Used ICS/FB-A 60 Fulton 60 Horsepower Gas Fired …

    Used Fulton 60 Horsepower Gas Fired Steam Boiler with: Boiler dimensions: 90 inches tall x 55 inch diameter. Flue outlet: 12 inch diameter. Output: 2,009,000 BTU/hr. Steam output: 2,070 lb/hr. 1.5 Hp Gas Burner Motor, 3450 RPM/60CY. Honeywell gas train.Learn More

  • fulton 15 hp steam boiler

    Fulton Classic and Edge Gas Fired Vertical Tubeless Steam Boilers This dimension is 6" less for oil fired units 4-50 HP and 12" less for oil fired units 15. 20. 25. 30. 50. 60. Boiler Connections. (N) Steam Outlet 15 …Learn More

  • FULTON ICS CLASSIC SERIES INSTRUCTION, …

    View and Download FULTON ICS Classic Series instruction, operation and maintenance manual online. Gas Fired Steam Boilers. ICS Classic Series boiler pdf manual download. Also for: Fb-f edge series, Ics 4, Ics 6, Ics 9.5, Ics 10, Ics 15, Ics 20, Ics 25, Ics 30Learn More

  • Used- Fulton Model ICS 20 Fuel Fired Vertical Tub

    Used- Fulton Model ICS 20 Fuel Fired Vertical Tubeless Steam Boiler. Natural gas, approximate 20 hp. Rated 690 pounds of steam per hour, approximately 840,000 btu/hour input, rated 15 psi. Includes a vertical condensate return system. Mounted on a common Learn More

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL - Fulton

    Fulton Ltd J DUAL FUEL MANUAL 02 2014 ISSUE 9 J SERIES - DUAL FUEL STEAM BOILER (Switchable Burner) (including optional Fully Modulating Burner) This manual must be available to the boiler operator at all times. INSTALLATION, OPERATION ANDLearn More

  • 50 HP FULTON Gas Fired - 296978 For Sale Used N/A

    50 HP FULTON Gas Fired Boiler. Image Scroll Left. Image Scroll Right. Fabricated Replacement Part. This listing is for a Third Party fabricated replacement part. Please See Description for Details. Asking Price: $3,805.00. Request Shipping Quote.Learn More

  • Steam Boilers & Equipment | Steam Boilers | Fulton …

    Fuel-Fired Steam Boilers The Fulton name has been synonymous with steam since the company first introduced the vertical tubeless steam boiler in 1949 and Fulton was established in Bristol in 1966. Fulton is still one of the world's leading manufacturers, producing an unrivalled range of multi-fuel-fired steam boilers, including the all-new, award-winning VSRT.Learn More

  • Used Fulton High Pressure Steam Boilers (Over 15 PSI) …

    Used Fulton Gas Fired Steam Boiler with: 1,035 pounds of steam per hour Natural gas fired Honeywell burner controls 1,350,000 BTU per hour Fulton ICS 10 High Pressure Steam Boiler 10 HP Used Fulton ICS 10 High Pressure Steam Boiler with: Fuel type: Number 2 oil Output: 345 pounds of steam per hour Shell thickness: 3/8 of an inch Head thickness: 1/2 of an inch Heating surfaceLearn More

  • Fulton The Classic (ICS / FB-A) FULTON 4-60 HP Vertical …

    Instruction, Operation, and Maintenance Manual BoilersLearn More

  • 2007 Fulton Thermal Corporation Natural Gas Fired Steam Boiler – 50 HP Mfg: Fulton Thermal Corporation Model: ICS 50 …

    2007 Fulton Thermal Corporation Natural Gas Fired Steam Boiler. Model: ICS 50. National Board: 104995. Rated at 50 hp with steam output of 1725 lbs./hr. Maximum input: 1992000 BTUH. MWP: 15 psi. Heating surface area: 150 sq. ft. ACME Transformer. CatalogLearn More

  • The Fulton Line of Vertical Tubeless Boilers

    Classic - Vertical Tubeless Boiler ICS 4-60 BHP TYPE: Vertical tubeless, steam or hot water SIZE: 4, 6, 9.5, 10, 15, 20, 30, 50, 60 BHP BURNER: Top mounted, down fired power burner. Adjustable air gate, gas or oil fired and combination fuel fired. Low Up toLearn More

  • fulton steam boiler – Industrial Boiler Catalogue

    Fulton Fuel Fired Steam Boiler Model# TCS-50. $6,500.00. Buy It Now. Fulton Boiler – Classic ICS-FB-A – Powerhouse Boilers New Boiler: The Fulton CLASSIC ICS/FB-4 Series Boiler is a the original vertical Learn More

  • [Fulton Fuel Fired Steam Boiler ICS-050-A] Hp Natural Plant

    1/7/2016 · BOILER no model ICS 050 A MD lbs STEAM hr sh HD 5/8 burner model g 50 e, nAturAl Gaza calorific value b. 5 million btu input, 2 million btu output, 150 Sig, nAturAl gAs FIRED, with Approximately national board no. BTU input 2, 520, 000 220v 60hz electrical rating.Learn More

  • Fulton Model I.C.S. 30HP Skid Mounted Steam Boiler | …

    One (1) Fulton Model ICS-30, 30 HP Fuel-Fired Steam Boiler: natural gas fired, modulated burner, fuel train built to CSD-1 standards, Honeywell Linkage Style, 240/1/60 motor voltage - TEFC, 120/60/1 control voltage through an incorporated step down transformer, complete with NEMA 1 control panel, and shall have an input of 1,256 CFH with an output of 1,005,000 BTU/hr (1,035lbs/hr). NOTE: Steam Learn More

  • Instruction, Operation, and Maintenance Manual Boilers

    Fulton The Classic (ICS / FB-A) FULTON 4-60 HP Vertical Learn More

  • Used Fulton Steam Boiler for sale. Top quality machinery …

    1-Used fulton model fb-015-a fuel fired steam boiler, boiler #86655. With national board stamp, boiler has stainless steel shrouding and is rated 518 md lbs./hour. …Learn More

  • Boiler, 9.5 HP, Fulton, 100 PSI, Gas-fired, ICS 9.5-LE (7) - …

    (7) Fulton boilers, 9.5 HP, Model number ICS 9.5-LE rated for 100 PSI, natural gas, 328 pounds per hour steam, fuel-fired steam boiler, 399,000 maximum BTUs per hour input, 13" maximum wc, 2.4" minimum wc. burner motor rating - 120 volt, 1-phase, 60Hz, 13.8 amps. controls rating - 120 volt, 1 phase, 6.0 amps. 3/8" head and shell thickness. Previously used at major biotechnology company. New in Learn More

  • Products - Fulton

    Fulton Products. Fulton has maintained a reputation for quality and excellence since 1949. From Steam and Hydronic boilers to Thermal Fluid Heaters and Custom Engineered Systems, Fulton has a product for virtually any industrial or commercial heating application.Learn More

  • fire tube boiler heat transfer coefficient - China Boiler …

    In a fire-tube boiler, hot products of combustion flowing through an array of thin-walled tubes are used to boil water flowing over the tubes. At the time of installation, the overall heat transfer coefficient was 400 Wm2 ∙ K. After 1 year of use, the inner and outer tube surfaces …Learn More

  • Boiler, 9.5 HP, Fulton, 100 PSI, Gas-fired, ICS 9.5-LE (7) - …

    (7) Fulton boilers, 9.5 HP, Model number ICS 9.5-LE rated for 100 PSI, natural gas, 328 pounds per hour steam, fuel-fired steam boiler, 399,000 maximum BTUs per hour input, 13" maximum wc, 2.4" minimum wc. burner motor rating - 120 volt, 1-phase, 60Hz, 13.8 amps. controls rating - 120 volt, 1 phase, 6.0 amps. 3/8" head and shell thickness. Previously used at major biotechnology company. New in Learn More

Hot News

Hot News

Hot News